Skip to content

Session Reports API

Session Report API allows you to read the session report information of HPC chargers with legacy CCBox in raw format. The query response contains an array of session report objects. To limit the query results for a selected time period or number of result items, use from, to, page, and limit parameters in your request body.

API Usage

See Token Management API for more information on how to create and use the access token.

Session Reports

Prepare Request Body

Set the following query parameters to prepare the request body.

  1. Charger ID to chargerId.
  2. Connector ID to connectorId.
  3. Additional query parameter for filtering the response. For more information, see Session Reports API Reference.

Example Request

Note

Use the server URL applicable to your region. See API Reference for available server URLs applicable to your region.

export ACCESS_TOKEN = <YOUR_ACCESS_TOKEN>

export CHARGER_ID = <YOUR_CHARGER_ID>
export CONNECTOR_ID = <YOUR_CONNECTOR_ID>

curl --location --request GET 'https://api.eu.depot.emobility.io/v1/sessionReports?chargerId=$CHARGER_ID&connectorId=$CONNECTOR_ID'
  --header 'Authorization: Bearer $ACCESS_TOKEN'

Response Body

Successful response returns 200 HTTP status code with response body as SessionReports schema. For more information, see Session Reports API Reference.

Example Response

{
    "items": [
        {
            "sessionId": 123456789,
            "vehicleId": "qwerty",
            "ocppStatus": [
                {
                    "value": "Available",
                    "eventTimestamp": "2021-03-23T16:54:56.087Z"
                },
                {
                    "value": "Preparing",
                    "eventTimestamp": "2021-03-23T16:59:11.670Z"
                },
                ...
            ],
            "detailStatus": [
                {
                    "key": "systemStatus",
                    "value": "0x00000000",
                    "eventTimestamp": "2021-03-23T00:48:26.437Z"
                },
                {
                    "key": "operationalStatus",
                    "value": "0x00000000",
                    "eventTimestamp": "2021-03-23T00:48:26.437Z"
                },
                ...
            ],
            "deviceStatus": [
                {
                    "status": "OPEN",
                    "deviceId": "Breaker",
                    "eventTimestamp": "2021-03-23T16:52:33.173Z"
                },
                {
                    "status": "STANDBY",
                    "deviceId": "Converter",
                    "errorCodes": [
                        {
                            "errorCode": "WARN: converter : sibcos 1: VQS disabled from operating mode(no:144)",
                            "errorCounter": 29
                        },
                        ...
                    ],
                    "eventTimestamp": "2021-03-23T16:55:11.088Z"
                }
            ],
            "energySocEnd": 98,
            "energySocStart": 76,
            "sessionTimeEnd": "2022-08-03T16:40:30.440Z",
            "energyChargeEnd": 1046400,
            "chargeParameters": [
                {
                    "maxPower": 450000,
                    "paramType": "Station",
                    "maxCurrent": 600,
                    "maxVoltage": 750,
                    "minCurrent": 0,
                    "minVoltage": 400,
                    "eventTimestamp": "2021-03-23T16:59:12.052Z"
                },
                {
                    "maxPower": 600000,
                    "paramType": "Request",
                    "maxCurrent": 800,
                    "maxVoltage": 750,
                    "minCurrent": 0,
                    "minVoltage": 0,
                    "eventTimestamp": "2021-03-23T16:59:12.186Z"
                },
                ...
            ],
            "energyPrimaryEnd": 293138710,
            "sessionTimeStart": "2022-08-03T16:20:30.661Z",
            "energyChargeStart": 1009136,
            "energyPrimaryStart": 293099449,
            "energyRequestedEnd": 1054122,
            "sessionMeterValues": [
                {
                    "key": "present_current",
                    "value": 0,
                    "eventTimestamp": "2021-03-23T16:54:35.287Z"
                },
                {
                    "key": "present_voltage",
                    "value": 3,
                    "eventTimestamp": "2021-03-23T16:59:08.685Z"
                },
                ...
            ],
            "energyRequestedStart": 1016608,
            "batteryAlignmentResults": {
                "inRange": true,
                "eventTimestamp": "2021-03-23T16:59:38.672Z",
                "presentVoltage": 633,
                "requestedVoltage": 633
            },
            "dcBreakerOpenConditions": {
                "current": 0,
                "voltage": 676,
                "eventTimestamp": "2021-03-23T17:13:44.735Z"
            }
        }
    ],
    "ChargerID": "xyz",
    "ConnectorID": "1"
}